| Tên thương hiệu: | ACEY |
| Số mẫu: | ACEY-BP24-100A150A |
| MOQ: | 1 bộ |
| Giá bán: | USD 5880~8130Set |
1-24 Series 100A Charge 150A Discharge BMS Tester Communication Protocol Test Optional
Product Description
ACEY-BP24-100A150A is with high automation level, featuring a friendly Chinese interface, fast testing speed and high testing accuracy. It has 13 performance tests including overcharge, overcharge recovery, overdischarge, overdischarge recovery, overcurrent (overcharge current and overdischarge current), internal resistance, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection time, equalization current, and equalization voltage.
Device Advantages
1. Cycle: cycle times: 1 to 9999 times
2. Laboratory mode, can arbitrarily adjust the voltage value of a section
3 Can continuously provide charging and discharging current.
4. Using programming, the device carries out the number of cycles of each indicator of the protection board without interruption.
5. Log tracking, With log function, including the test of the entire process of operation records, abnormal records, can be used for the traceability of the test process.
6. Data processing, human-machine interface
7. Test data is saved in EXCEL file.
8. RS232 interface is used for the interface between the device and the host computer, which can ensure the stability and real-time data acquisition.
9. Accuracy calibration/software calibration
10. With sweeping code start function
11. MES system interface
12. Active equalization (can be customized)
13. Equalization current (customizable)
14. Communication protocol test (optional)
Tester Function
| No. | Function | Range | Accuracy | unit |
| 1 | Self-consumption of single cell | 0--500 | ±0.1 | uA |
| 2 | Self-consumption | 0--5000 | ±1 | uA |
| 3 | Overcharge voltage | 500--5000 | ±1 | mV |
| 4 | Overcharge recovery voltage | 500--5000 | ±1 | mV |
| 5 | Overcharge voltage protection delay | 0--10000 | ±1 | mS |
| 6 | Overdischarge voltage | 500--5000 | ±1 | mV |
| 7 | Overdischarge recovery voltage | 500--5000 | ±1 | mV |
| 8 | Overdischarge voltage protection delay | 0--10000 | ±1 | mS |
| 9 | Overcharge protection current protection value | 0.1--50 | ±0.01 | A |
| 10 | Overcharge protection current protection delay | 0--20000 | ±1 | mS |
| 11 | Overdischarge protection current protection value | 0.1--120 | ±0.01 | A |
| 12 | Overdischarge protection current protection delay | 0.1--20000 | ±1 | mS |
| 13 | Equalization function opening voltage | 500--5000 | ±1 | mV |
| 14 | Equalizing current | 1--500 | ±1 | mA |
| 15 | Charging current | 0.1--30 | ±0.01 | A |
| 16 | Discharging current | 0.1--120 | ±0.01 | A |
| 17 | Charging time | 0--30 | ±1 | S |
| 18 | Discharging time | 0--60 | ±1 | S |
| 19 | The difference of single cell self-consume | 0-500 | ±0.1 | uA |
| 20 | Resistance | 0-999 | ±1 | mΏ |
| 21 | Short circuit protection time | 0--5000 | ±1 | uS |
| 22 | The charging voltage of single cell | 500--5000 | ±1 | mV |
| 23 | The discharging voltage of single cell | 500--5000 | ±1 | mV |
| 24 | Open circuit voltage | 160000 | ±1 | mV |
| 25 | Number of voltage analogs | 24 | 0 | PCS |
Parameter of the main loop test
| Project | Parameter |
| Voltage | 160000mV |
| Voltage resolution | 1mV |
| Voltage accuracy | ±0.1% |
| Discharging current | 0.1A ~150A |
| Current resolution | 1mA |
| Current accuracy | ±(0.1%) |
| Other | The charging and discharging circuits are completely separated |
Parameter of every series cell
| Project | Parameter |
| Output voltage of every cell | 500mV ~ 5000mV |
| Input voltage of every cell | 500mV ~ 5000mV |
| Voltage resolution | 1mV |
| Voltage accuracy | ±0.05% |
| Equalization current | 500mA |
Product Display
![]()