| Brand Name: | ACEY |
| Model Number: | ACEY-BP24-50A120A |
| MOQ: | 1 Set |
| Price: | USD 5880~8130Set |
| Payment Terms: | T/T,PayPal,L/C,Western Union |
| Supply Ability: | 200 Sets/Month |
1-24 Series 50A Charge 120A Discharge BMS Tester High Automation Fast Accurate Comprehensive Protection
ACEY-BP24-50A120A is with high automation level, featuring a friendly Chinese interface, fast testing speed and high testing accuracy. It has 13 performance tests including overcharge, overcharge recovery, overdischarge, overdischarge recovery, overcurrent (overcharge current and overdischarge current), internal resistance, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection time, equalization current, and equalization voltage.
| No. | Function | Range | Accuracy | unit |
|---|---|---|---|---|
| 1 | Self-consumption of single cell | 0--500 | ±0.1 | uA |
| 2 | Self-consumption | 0--5000 | ±1 | uA |
| 3 | Overcharge voltage | 500--5000 | ±1 | mV |
| 4 | Overcharge recovery voltage | 500--5000 | ±1 | mV |
| 5 | Overcharge voltage protection delay | 0--10000 | ±1 | mS |
| 6 | Overdischarge voltage | 500--5000 | ±1 | mV |
| 7 | Overdischarge recovery voltage | 500--5000 | ±1 | mV |
| 8 | Overdischarge voltage protection delay | 0--10000 | ±1 | mS |
| 9 | Overcharge protection current protection value | 0.1--50 | ±0.01 | A |
| 10 | Overcharge protection current protection delay | 0--20000 | ±1 | mS |
| 11 | Overdischarge protection current protection value | 0.1--120 | ±0.01 | A |
| 12 | Overdischarge protection current protection delay | 0.1--20000 | ±1 | mS |
| 13 | Equalization function opening voltage | 500--5000 | ±1 | mV |
| 14 | Equalizing current | 1--500 | ±1 | mA |
| 15 | Charging current | 0.1--30 | ±0.01 | A |
| 16 | Discharging current | 0.1--120 | ±0.01 | A |
| 17 | Charging time | 0--30 | ±1 | S |
| 18 | Discharging time | 0--60 | ±1 | S |
| 19 | The difference of single cell self-consume | 0-500 | ±0.1 | uA |
| 20 | Resistance | 0-999 | ±1 | mΏ |
| 21 | Short circuit protection time | 0--5000 | ±1 | uS |
| 22 | The charging voltage of single cell | 500--5000 | ±1 | mV |
| 23 | The discharging voltage of single cell | 500--5000 | ±1 | mV |
| 24 | Open circuit voltage | 102000 | ±1 | mV |
| 25 | Number of voltage analogs | 24 | 0 | PCS |
| Project | Parameter |
|---|---|
| Voltage | 102000mV |
| Voltage resolution | 1mV |
| Voltage accuracy | ±0.1% |
| Discharging current | 0.1A ~120A |
| Current resolution | 1mA |
| Current accuracy | ±(0.1%) |
| Other | The charging and discharging circuits are completely separated |
| Project | Parameter |
|---|---|
| Output voltage of every cell | 500mV ~ 5000mV |
| Input voltage of every cell | 500mV ~ 5000mV |
| Voltage resolution | 1mV |
| Voltage accuracy | ±0.05% |
| Equalization current | 500mA |
![]()