| ชื่อแบรนด์: | ACEY |
| เลขรุ่น: | เอซีย์-BCT560-64P |
| ขั้นต่ำ: | 1 ชุด |
| ราคา: | USD 6600~15960/Set |
| เงื่อนไขการจ่ายเงิน: | T/T, เพย์พาล, แอล/C, เวสเทิร์นยูเนี่ยน, MoneyGram |
| ความสามารถในการจําหน่าย: | 200 ชุด/เดือน |
5V 60A 64 Channels Prismatic Lithium Battery Testing Machine With Alligator Clips
Product Description
ACEY-BCT560-64P prismatic lithium battery testing machine is primarily designed for capacity testing and cycle life testing of prismatic batteries. The system features an energy regeneration function, feeding discharge energy back into the power grid to significantly reduce power consumption and heat generation. Alligator clip fixtures are used for reliable connection to battery terminals, offering flexibility for different prismatic cell designs.
Energy Feedback Principle
When charging, grid AC power is converted by the bidirectional supply into 14 V DC and delivered to the battery through the current-control module for regulated charging and data monitoring. During discharge, the process runs in reverse: the cell output is raised to 15 V DC, then converted back to AC and returned directly to the factory power network. In this way, the energy released during discharge is reused instead of being dissipated as heat.
Supported Battery Dimensions
| Length | 80–300 mm |
| Thickness | 15–75 mm |
| Height | 80–230 mm |
| Terminal spacing | 50–250 mm |
Main Technical Parameter
| Number of equipment channels | The whole machine has 64chs |
| External dimension | Length 968* width 901* height 1840 (customized version, the size is subject to the actual model |
| Case color | Standard gray / black (customizable) |
| Clamp type | Flat head clamp + Alligator clips |
| Clamp spring | 78.5MM |
| Channel control mode | Each channel can be started, stopped, suspended, continued and protected independently. |
| Each channel has independent constant voltage and current. Hardware control circuit | |
| The accuracy of charging current and discharging current of each channel can be calibrated automatically by software | |
| Working power supply | Three phase five wire AC380V土10%, 50Hz |
| Power factor | ≥0.99 |
| AC current distortion rate | ≤2% |
| Charging efficiency of the whole machine | ≥75% |
| Feed conversion efficiency | ≥70% |
| Power consumption work | ≤ 23KW |
| Equipment failure rate | <1% |
| Work environment | Temperature -10~40°C. Relative humidity 80% |
| Heat dissipation mode | Natural wind in, upward exhaust |
| Voltage measurement range | DC 0~5V |
| Battery voltage range | Charge DC 0~4.5V; discharge DC 4.5~2V |
| Constant voltage range | DC 2~4.5V |
| Voltage accuracy | ±(0.05% reading + 0.05% full), resolution ratio 1mV |
| Voltage stability | ≤(±1mV) |
| Current range | Charge DC 120mA~60A; Discharge DC 120mA~60A |
| Current accuracy | ±(0.05% reading + 0.05% full), resolution ratio 1mV |
| Current stability | ≤(±1mA) |
| Negative pressure range | (-100KPa-0)adjustable |
| Control mode | Computer control, can control the whole cabinet with scanning function |
| Communication mode | 485s port communication (port rate 57600)/ TCP |
| Process settings | Up to 32 steps and 256 cycles can be set |
| Charging mode | Constant current; constant pressure; constant current & pressure |
| Charging cut-off conditions | Voltage, current, time, capacity |
| Discharge mode | Permanent flow, constant power, constant resistance |
| Discharging cut-off conditions | Voltage, time, and capacity |
| Protection function | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power off protection, data breakpoint recovery |
| Time frame | 0~3000 min / step in min |
| Time accuracy | ≤±0.1% |
| Sampling inspection cycle | 1s-60s optional |
| Battery sorting | Divide according to capacity, time, open-circuit voltage, discharge platform, etc. |
| Data processing | Can record voltage, current, time, capacity etc, automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, median voltage, provide data curve and cycle diagram; can output text, excel, word or mdb format data file |
| Basic function of software | 1. The software supports various connections, such as manual pause continuation, software shutdown continuation, power outage, disconnection in equipment communication, abnormal stop continuation; |
| 2. Support bar code scanning, scanning one-dimensional code, QR code, channel jump scanning, loading scanning and other scanning methods; | |
| 3. Local test detailed data storage, can view the current test data and historical data of each channel at any time, have data and curve corresponding two ways, and support excel report in single or batch form, and can set the test end automatic data export according to the need. | |
| 4. Support capacity sorting, and grade the battery sorting; | |
| 5. Support the qualified judgment after the test, and judge the pass / ng results according to the specified cycle capacity, voltage, time and other information; | |
| 6. Support various step protection and global voltage, current, temperature abnormal protection, and abnormal alarm, support battery pack overcharge, overdischarge protection test; | |
| 7. Support channel parallel (according to equipment); | |
| 8. Support unit conversion; | |
| 9. Support database server background storage or MES docking; | |
| 10. Software offline protection; |
Product Display
![]()
![]()