Battery Comprehensive Tester
Created with Pixso.

Lithium Ion Battery Pack Comprehensive Tester 200V 100A Charge 400A Discharge

Lithium Ion Battery Pack Comprehensive Tester 200V 100A Charge 400A Discharge

Nombre De La Marca: ACEY
Número De Modelo: ACEY-BIT200-100A400A
MOQ: 1 juego
Precio: USD 2280~21980/Set
Condiciones De Pago: T/T, PayPal, L/C, Western Union, MoneyGram
Capacidad De Suministro: 200 sistemas/mes
Información detallada
Lugar de origen:
Porcelana
Certificación:
CE
Garantía:
1 año de garantía con soporte de por vida
Servicio postventa:
Soporte técnico 24 horas al día, 7 días a la semana
Rango de voltaje:
0~200V
Corriente de carga:
0~100A
Descarga de corriente:
0 ~ 400 A
Resolución actual:
0.001A
Precisión actual:
±(0,1 % RD + 0,1 FS)
Fuente de alimentación de entrada:
CA 200~240V 50/60HZ
Detalles de empaquetado:
Caja de madera contrachapada
Resaltar:

400A lithium cell tester

,

Comprehensive lithium cell tester

,

Comprehensive lithium ion battery analyzer

Descripción de producto

Lithium Ion Battery Pack Comprehensive Tester 200V 100A Charge 400A Discharge 

 

 

Product Description

ACEY-BIT200-100A400A battery charge discharge test equipment is used for comprehensive performance testing of lithium-ion battery packs for energy storage modules, electric vehicles, electric scooters, AGVs, and garden tools. It supports all series of power batteries with CH+ / P+ / CH− / P− terminals, and is suitable for both semi-finished and finished product testing during production. The equipment can also be used as an electronic load for long-duration current draw testing of battery packs.

 

Main Technical Parameter

Voltage Total Voltage 0–200 V 0.1 mV ±0.1% RD + 0.1% FS
Internal Resistance AC Internal Resistance 0–4000 mΩ 0.001 mΩ ±0.1% RD + 0.1% FS
Charge DC Internal Resistance 0–4000 mΩ 0.001 mΩ ±0.1% RD + 0.1% FS
Discharge DC Internal Resistance 0–4000 mΩ 0.001 mΩ ±0.1% RD + 0.1% FS
Charging Static Voltage 0–200 V 0.1 mV ±0.1% RD + 0.1% FS
Charge Current 0–100 A 0.001 A ±0.1% RD + 0.1% FS
Charge Time 3 s
Charge Voltage 0–200 V 0.1 mV ±0.1% RD + 0.1% FS
Charge Delay 0–3 s 1 ms ±0.1% RD + 0.1% FS
Charging Power 12 kW
Discharging Static Voltage 0–200 V 0.1 mV ±0.1% RD + 0.1% FS
Loaded Voltage 0–200 V 0.1 mV ±0.1% RD + 0.1% FS
Discharge Current 0–400 A 0.001 A ±0.1% RD + 0.1% FS
Discharge Time (400 A) 3 s
Over-current Delay 0–3 s 1 ms ±0.1% RD + 0.1% FS
Discharging Power 80 kW
Short Circuit Short-circuit Time 0–2000 μs 1 μs ±0.1% RD + 0.1% FS
Resistance NTC 0–100 kΩ 0.001 kΩ ±0.1% RD + 0.1% FS
Identification Resistor 0–100 kΩ 0.001 kΩ ±0.1% RD + 0.1% FS

 

Test Items

No. Test Function Description
1 Voltage Voltage is measured twice: first as no-load voltage, and again after all tests are completed, especially after short-circuit protection testing, to verify battery condition. The second voltage is typically slightly lower than the first.
2 Internal Resistance Measures the battery’s AC internal resistance at 1000 Hz.
3 Charge Over-current Protection Current Verifies whether the battery has automatic protection when charge current is excessive. This is critical to prevent damage to the BMS. If no protection exists, continuous charge current is selected instead.
4 Charge Over-current Protection Delay Sets a current value and measures the time from current generation to BMS protection activation.
5 Continuous Charge Current For batteries without charge over-current protection, the charge current is usually set equal to the charger current.
6 Continuous Charge Voltage Monitoring During continuous charging, upper and lower voltage limits can be set to determine whether the battery voltage exceeds the allowable range.
7 Discharge Over-current Protection Current When discharge current exceeds a set value, protection is triggered, typically according to datasheet specifications.
8 Discharge Over-current Protection Delay Sets a current value and measures the time from current generation to BMS protection activation.
9 Continuous Discharge Current Represents the normal operating discharge current. Abnormal BMS conditions may cause inability to sustain discharge.
10 Continuous Discharge Voltage During continuous discharge, voltage upper and lower limits can be set to monitor abnormal voltage conditions.
11 Short-circuit Protection Time Measures the BMS response time when the battery terminals are momentarily shorted. Faster response (typically <1000 μs) provides better protection. Excessive short-circuit time may indicate high loop resistance and requires analysis.
12 Cell Voltage (Optional) Dynamic monitoring of individual cell voltage during charge and discharge.
13 Charge Voltage Rise Compares end-of-charge voltage with static voltage to determine voltage rise.
14 Discharge Voltage Drop Compares end-of-discharge voltage with initial voltage to determine voltage drop.
15 Charge DC Internal Resistance Calculated by dividing the voltage rise after charging by the set charge current.
16 Discharge DC Internal Resistance Calculated by dividing the voltage drop after discharging by the set discharge current.
17 Identification Resistance Tests ID and NTC resistance values.
18 Secondary Discharge Over-current Protection Current Secondary protection triggered when discharge current exceeds a preset value, typically per datasheet requirements.
19 Secondary Discharge Over-current Protection Time Measures the protection response time from current generation to BMS cutoff.
20 Communication Test (Optional) Supports RS485, RS232, CAN, and other communication interfaces.
21 Insulation & Withstand Voltage (Optional) Insulation resistance and dielectric withstand voltage testing.

 