Intervallo di tensione:
5~30 V
Intervallo corrente:
0,1~20 A (carica e scarica)
Precisione:
±(0,1% RD + 0,1 FS)
Potenza in uscita:
Massimo. 600 W (canale singolo)
Imballaggi particolari:
Custodia in compensato
Evidenziare:

18 Channel Battery Pack Tester

,

Lead Acid Battery Pack Tester

,

30V lithium ion battery tester

Descrizione di prodotto

18-Channel 30V Battery Pack 20A Charge 20A Discharge Tester For Lithium/Lead-acid/NiMH/NiCd Battery

 

 

Product Description

ACEY-BA3020-18 battery aging machine is used for aging tests of various battery packs, including NCM, LFP, lead-acid, and NiMH/NiCd types, supporting both common-port and individual-port battery packs. The cabinet provides adjustable and stable output voltage from 5V to 30V and current from 100mA to 20A. It is widely used in battery module production testing, as well as for charge and discharge performance testing of batteries in vacuum cleaners, power tools, electric scooters, and energy storage systems.

Key functions include cycle life testing, capacity testing, charge/discharge performance testing, and temperature characteristic testing, providing comprehensive support for battery performance evaluation and quality control.

 

Test Items

  1. High Precision: ±(0.1%RD+0.1%FS) with stable and reliable operation.
  2. Flexible Grouping: Each channel can be freely grouped with independent charge/discharge settings.Comprehensive Protection: Includes input/output protection, hardware/software protection, reverse connection protection, and power-off resume protection.
  3. Smooth Start: Channels start without inrush current; seamless transition from constant current to constant voltage with no current spikes.
  4. Centralized Management: Networked control allows a single computer to manage the entire cabinet, supporting remote monitoring.
  5. Modular Design: Plug-in cabinet design for easy maintenance and future expansion.
  6. Data Management: Clear and comprehensive real-time monitoring, with capability to upload data to MES systems.

 

Main Technical Parameter

No. Project Functional Requirements
1 Number of cabinet channels 18 channels
2 Channel action mode Completely independent
3 Main channel operating mode Charging: constant current CC, constant current constant voltage charging CCCV; Discharge: constant current discharge CD, constant power CP;
Let it stand and stop.
Main Channel Test Stop Conditions Time, voltage, current, capacity, etc.
4 Main channel voltage Charging voltage range 5V ~ 30V
Discharge voltage range 5V ~ 30V
Accuracy ±(0.1%RD+0.1%FS)
Resolution 1mV
Main channel current Maximum output current Charge current 20A, discharge current 20A,
Minimum output current 100mA
Accuracy ±(0.1%RD+0.1%FS)
Resolution 1mA
Power Output power Single channel continuous operation maximum power 600W
Auxiliary channel parameter cutoff function You can set the main channel step to stop or switch when the auxiliary channel signal reaches a certain condition.
5 Control Procedure 1. Support data protection due to power failure, manual stop and connection from data files
Continued testing.
Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit,
Current upper limit, voltage and current trend.
The auxiliary channel protection conditions can be set, and the parameters can be set include: upper voltage limit, lower voltage
Limit, upper temperature limit, lower temperature limit.
Number of cycles Maximum 9999
Step time unit Support h, min, s format
Data upload interval Minimum 5S
6 Data Display Mode Cycle List There are cycle number, charge/discharge capacity, charge/discharge efficiency, Charge/discharge energy, charge/discharge average voltage, etc.
Process List There are process serial number, working mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc.
Detail List There are record serial numbers, system time, cumulative time, voltage, Current, energy, power, etc.
7 Data Export Method The data can be exported into EXCEL and chart files, which can provide a variety of data analysis curves such as charge and discharge efficiency, charge and discharge curves, voltage, capacity, current time characteristics, etc.
line into EXCEL.

 

Product Display