Dettagli dei prodotti

Created with Pixso. Casa Created with Pixso. prodotti Created with Pixso.
Battery Pack Tester
Created with Pixso.

60V 50A Charge And Discharge 8 Channels Aging Machine Battery Pack Testing Machine For Lithium Battery

60V 50A Charge And Discharge 8 Channels Aging Machine Battery Pack Testing Machine For Lithium Battery

Marchio: ACEY
Numero di modello: ACEY-BA6050-8
MOQ: 1 set
Prezzo: USD 4630~6940Set
Informazione dettagliata
Luogo di origine:
Cina
Certificazione:
CE
Intervallo di tensione:
8-60 V
Intervallo di corrente di carica e scarica:
100 mA ~ 50 A
Precisione:
± (0,05%RD+0,05%FS)
Canali:
8
Evidenziare:

60V 50A battery testing system

,

battery testing system Aging Machine

,

60V battery life cycle tester

Descrizione di prodotto

60V 50A Charge And Discharge 8 Channels Aging Machine Battery Pack Testing Machine For Lithium Battery



Product Description

ACEY-BA6050-8 is an energy feedback testing machine designed for Li-ion (NCM/LFP), lead-acid, NiMH, and NiCd battery packs. Supporting voltage ranges of 8V~60V and adjustable current (100mA~50A), it is ideal for battery module production testing, EV/HEV power system high-current validation, and routine maintenance. With 8 independent channels, the device achieves parallel testing of multiple packs while maintaining ±(0.05%RD+0.05%FS) accuracy and seamless CCCV (Constant Current-Constant Voltage) charging.


Product Features

1. Voltage and current accuracy ± (0.05%RD+0.05%FS), data recording time 5S/time, high stability.

2. The equipment can accommodate up to 8 channels, and can be set for independent charging and discharging conditions after free grouping for each channel.

3. complete input and output, software and hardware protection, reverse connection protection, power failure renewal, short circuit protection, etc.

4. Channel start without inrush current, constant current to constant voltage seamlessly over, without any current surges

5.Network integrated management, a computer centralized control, support remote monitoring

6. Modular design of power unit, easy to produce, easy to maintain

7. Clear and comprehensive data, real-time monitoring and uploading to MES system


Software workstep setting requirements

NO Item Requirement
1 Charge 1.Constant current charging, where the channel is output at a constant current and the current output is soft-started, with no current impact.
2. Continuous mode of constant current and constant voltage charging, limited voltage output and current output at the same time, hardware automatic switching, with current hardware soft start, constant current to constant voltage without inrush current.
2 Discharge Constant current discharge, the channel discharges at a constant current, the current control adopts soft start, no current shock.
3 Resting The current circuit is cut off, but data collection is not stopped
4 Cycler Cycle testing of work steps according to actual needs, multi-layer cycle nesting is possible
5 Stop The channel is completely stopped and the battery circuit is completely disconnected from the device


Technical Parameter

NO Item Function requirement
1 Channel 8
2 Action Mode Completely independent
3 Main channel work mode Charging: constant current and constant voltage charging CCCV.&CC
Discharge: constant current discharge CD.& CP
Resting, stopping
Main channel test abort condition Time, voltage, current, capacity, etc
4 Voltage of main channel Voltage range of Charge&discharge  8V-60V
Accuracy ±(0.05%RD+0.05%FS)
Min discharge voltage 8V(port voltage)
Resolution 1mV
Current of main channel Maximum output current 50A
Minimum output current 100mA
Accuracy ±(0.05%RD+0.05%FS)
Resolution 1mA
Power Output Single channel continuous operation maximum power 3KW
Auxiliary channel parameter cut-off function The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions.
5 Control program Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files.
Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend.
Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit.
Cycle times Max 9999
Work step time unit h,min,s are available
Data logging Min 5S
6 Data display method Loop List cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc.
Process List process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc.
Detailed list There are record serial number, system time, accumulated time, voltage, current, energy, power, etc.
7 Data export method The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL.
8 Curve Type X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely.
Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely.

Software protection Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection.


Hardware protection Battery reversal, over-current protection, over-voltage protection, short-circuit protection.
9 Alarm function The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection.
10 Output wire Four-wire connection mode with separate current and voltage lines.
11 Maintainability Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period.
12 Test channel and battery pack connection method Alligator clamp
13 Equipment testing environment and technical requirements Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant
Working environment: temperature -10℃~40 / humidity: 10%90%
14 Communication function (Optional) smbus,I2C,HDQ,SPI,CAN,RS485
Real-time reading of parameter information (voltage, temperature, current, capacity) in BMS supports DBC import and self-editing.


Product Display