18-Channel 30V Battery Pack 20A Charge 20A Discharge Tester For Lithium/Lead-acid/NiMH/NiCd Battery
Product Description
ACEY-BA3020-18 battery aging machine is used for aging tests of various battery packs, including NCM, LFP, lead-acid, and NiMH/NiCd types, supporting both common-port and individual-port battery packs. The cabinet provides adjustable and stable output voltage from 5V to 30V and current from 100mA to 20A. It is widely used in battery module production testing, as well as for charge and discharge performance testing of batteries in vacuum cleaners, power tools, electric scooters, and energy storage systems.
Key functions include cycle life testing, capacity testing, charge/discharge performance testing, and temperature characteristic testing, providing comprehensive support for battery performance evaluation and quality control.
Test Items
Main Technical Parameter
| No. | Project | Functional Requirements | ||
| 1 | Number of cabinet channels | 18 channels | ||
| 2 | Channel action mode | Completely independent | ||
| 3 | Main channel operating mode | Charging: constant current CC, constant current constant voltage charging CCCV; Discharge: constant current discharge CD, constant power CP; | ||
| Let it stand and stop. | ||||
| Main Channel Test Stop Conditions | Time, voltage, current, capacity, etc. | |||
| 4 | Main channel voltage | Charging voltage range | 5V ~ 30V | |
| Discharge voltage range | 5V ~ 30V | |||
| Accuracy | ±(0.1%RD+0.1%FS) | |||
| Resolution | 1mV | |||
| Main channel current | Maximum output current | Charge current 20A, discharge current 20A, | ||
| Minimum output current | 100mA | |||
| Accuracy | ±(0.1%RD+0.1%FS) | |||
| Resolution | 1mA | |||
| Power | Output power | Single channel continuous operation maximum power 600W | ||
| Auxiliary channel parameter cutoff function | You can set the main channel step to stop or switch when the auxiliary channel signal reaches a certain condition. | |||
| 5 | Control Procedure | 1. Support data protection due to power failure, manual stop and connection from data files | ||
| Continued testing. | ||||
| Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, | ||||
| Current upper limit, voltage and current trend. | ||||
| The auxiliary channel protection conditions can be set, and the parameters can be set include: upper voltage limit, lower voltage | ||||
| Limit, upper temperature limit, lower temperature limit. | ||||
| Number of cycles | Maximum 9999 | |||
| Step time unit | Support h, min, s format | |||
| Data upload interval | Minimum 5S | |||
| 6 | Data Display Mode | Cycle List | There are cycle number, charge/discharge capacity, charge/discharge efficiency, Charge/discharge energy, charge/discharge average voltage, etc. | |
| Process List | There are process serial number, working mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
| Detail List | There are record serial numbers, system time, cumulative time, voltage, Current, energy, power, etc. | |||
| 7 | Data Export Method | The data can be exported into EXCEL and chart files, which can provide a variety of data analysis curves such as charge and discharge efficiency, charge and discharge curves, voltage, capacity, current time characteristics, etc. | ||
| line into EXCEL. | ||||
Product Display
![]()
![]()