Aantal kanalen:
32 kanalen
Spanningsmeetbereik:
-6V ~ 6V
voltagenauwkeurigheid:
±0,03% FS, resolutie 1mV
Huidig ​​bereik:
Opladen en ontladen 20mA~200A
Huidige nauwkeurigheid:
±0,03% FS, resolutie 1mA
Compatibele batterij:
Li-ionbatterij/loodzuurbatterij/Ni-Cd-batterij/Ni-MH-batterij
Verpakking Details:
Multiplex kast
Markeren:

32CH Lithium Cell Grading Machine

,

Ni MH Lithium Cell Grading Machine

,

6V 200A hybrid battery cell tester

Productomschrijving

6V 200A 32 Channels Battery Life Cycle Tester For Li-ion/Lead-acid/Ni-Cd/Ni-MH Battery

 

 

Product Description

ACEY-HRCDS-6V200A-32CH battery life cycle tester is designed for battery cycle life testing and quality control in both production and laboratory environments. It is applicable to a wide range of battery chemistries, including Lithium-ion, Lead-acid, Nickel-Cadmium (Ni-Cd), and Nickel-Metal Hydride (Ni-MH) batteries. The system supports comprehensive test functions such as cycle life testing, capacity testing, charge and discharge performance evaluation, charge retention testing, charge/discharge efficiency testing, overcharge and over-discharge tolerance testing, pulse testing, and simulated working condition tests, providing reliable data for battery performance assessment and verification.

 

Equipment Features

  • Current supports multiple ranges: 0.02A-50A (accuracy ≤0.03%FS), 50A-100A (accuracy ≤0.03%FS), 100A-200A (accuracy ≤0.03%FS).
  • Minimum discharge voltage -6V.
  • High Reliability and Low Noise: Compact and flexible for laboratory use, with high energy density.
  • Energy Feedback (Up to 75% Grid Efficiency): Bi-directional energy feedback during charge and discharge reduces electricity costs and air-conditioning expenses caused by heat dissipation.
  • Fixture Contact Impedance Monitoring: Prevents safety issues due to poor terminal contact or oxidation from prolonged use.
  • CCCV Charging: Smooth CCCV transition with no voltage or current spikes, effectively preventing localized heating, tab delamination, micro-short circuits, and unwanted protection triggers on PCBs.
  • Stable and Accurate Current/Voltage Sampling: Uses high-precision, wide-dynamic-range ADC units for long-term measurement stability and accuracy.
  • Dynamic Load (DL) Protection: Safeguards batteries during charge/discharge, preventing arcing or current surges caused by loose connectors, and protects sensitive electronic components such as MOSFETs and fuses.

  • Voltage Clamping Function: Limits voltage during battery protection activation or device abnormality to prevent damage to the battery or battery protection board.

  • ECD & EVD Protection: Prevents charging or discharging of batteries that fail selection criteria, avoiding unnecessary protection triggers.

  • Third-Party Equipment Control: Supports integration with external devices (e.g., thermal chambers) during testing; relevant test data is stored together for comprehensive battery testing (optional, third-party protocol required).

  • Capacity Calibration Function: Sets the discharge capacity of a specific test step as a reference for current and capacity evaluation in various cycle tests.

  • RSOC Capacity Recharge Testing: Uses the previous cycle’s charge/discharge capacity (or accumulated capacity from multiple steps) as the baseline for subsequent step evaluation.

 

Main Technical Parameter

No. Item ACEY-HRCD6V200A-32CH
1 Main channels 8CH/ module
2 Channel working mode Completely independent.
3 Main channel working mode Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV.
Discharge: CD, CP, CR, DCCV.
Still, Pulse test, Working Condition test, DCIR test.
Main channel test cutoff condition Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc.
4 Main channel Voltage Single channel test range -6V~6V
Min. discharge voltage -6V
Accuracy ≤0.03%FS(@25℃±10),≤0.1%FS(@0-15℃,35-45℃)
Resolution 1mV
Main channel Current Single channel test range ±200A
Min. output current 20mA
Accuracy(automatic switching) 20mA--50A:0.03%FS(@25℃±10)
50A--100A:0.03%FS(@25℃±10)
100A--200A:0.03%FS(@25℃±10)
Resolution 1mA
Current start response time 5ms(10%FS90%FS)
Time Resolution 10ms
Auxiliary temperature (Optional) Range 20℃100℃
Accuracy ±1℃(0℃70℃)
Resolution 0.1℃
Power Output power Single channel continuous working power 1200W
Stability ±0.1%FS
5 Communication LAN
6 Control program Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online.
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc.
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature.
Cycle time Max. 9999
Programmable step Max. 9999
Nested loop Max. 10 layers
Step time range No limit, support h, min, s
Data record Maximum recording time:10ms,Voltage≤0.03%FS,Current≤0.03%FS
Program feature Each step has one or multiple exit
7 Data display Cycle list Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc.
Process list Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc.
Detail list Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc.
8 Data export Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc.
9 Data saving Save as files
10 Curves type X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity.
Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc.
11 Software protection Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection.
Hardware protection Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection.
Warning function Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically.
12 Barcode scan Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system.
13 Sampling terminals Four-polar sampling. Copper nose or other fixture.
14 Energy consumption Discharge power feedback to grid
15 Cooling method Forced Fan-cooled
Noise Less than 70dB
IP grade IP20
16 Repair Modularized structure. Can be replaced or repair with spare parts.

 

Product Specification

Cabinet size 600*800*1980(Device direct line out)
600*990*1980(Device with adapter)
Weight 300KG
Channels number 32CH

 

Working Environment

  • Power Supply (Single Unit): AC 380V ±10%, 50 Hz ±5%.

  • Power Supply (Complete Cabinet): AC 380V ±10%, 50 Hz ±5%.

  • Maximum Input Power (Complete Cabinet): 51.2 kW (32 channels).

  • Ambient Temperature: 0–45°C.

  • Ambient Humidity: ≤ 85% RH (non-condensing).

  • Operating Environment: Free from strong vibration, corrosive gases, and flammable or explosive gases.

 