| ব্র্যান্ড নাম: | ACEY |
| মডেল নম্বর: | ACEY-HRCDS-6V200A-32CH |
| MOQ: | 1 সেট |
| দাম: | USD 2480~19600/Set |
| অর্থ প্রদানের শর্তাবলী: | টি/টি, পেপাল, এল/সি, ওয়েস্টার্ন ইউনিয়ন, মানিগ্রাম |
| সরবরাহের ক্ষমতা: | 200 সেট/মাস |
6V 200A 32 Channels Battery Life Cycle Tester For Li-ion/Lead-acid/Ni-Cd/Ni-MH Battery
Product Description
ACEY-HRCDS-6V200A-32CH battery life cycle tester is designed for battery cycle life testing and quality control in both production and laboratory environments. It is applicable to a wide range of battery chemistries, including Lithium-ion, Lead-acid, Nickel-Cadmium (Ni-Cd), and Nickel-Metal Hydride (Ni-MH) batteries. The system supports comprehensive test functions such as cycle life testing, capacity testing, charge and discharge performance evaluation, charge retention testing, charge/discharge efficiency testing, overcharge and over-discharge tolerance testing, pulse testing, and simulated working condition tests, providing reliable data for battery performance assessment and verification.
Equipment Features
Dynamic Load (DL) Protection: Safeguards batteries during charge/discharge, preventing arcing or current surges caused by loose connectors, and protects sensitive electronic components such as MOSFETs and fuses.
Voltage Clamping Function: Limits voltage during battery protection activation or device abnormality to prevent damage to the battery or battery protection board.
ECD & EVD Protection: Prevents charging or discharging of batteries that fail selection criteria, avoiding unnecessary protection triggers.
Third-Party Equipment Control: Supports integration with external devices (e.g., thermal chambers) during testing; relevant test data is stored together for comprehensive battery testing (optional, third-party protocol required).
Capacity Calibration Function: Sets the discharge capacity of a specific test step as a reference for current and capacity evaluation in various cycle tests.
RSOC Capacity Recharge Testing: Uses the previous cycle’s charge/discharge capacity (or accumulated capacity from multiple steps) as the baseline for subsequent step evaluation.
Main Technical Parameter
| No. | Item | ACEY-HRCD6V200A-32CH | ||
| 1 | Main channels | 8CH/ module | ||
| 2 | Channel working mode | Completely independent. | ||
| 3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV. | ||
| Discharge: CD, CP, CR, DCCV. | ||||
| Still, Pulse test, Working Condition test, DCIR test. | ||||
| Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
| 4 | Main channel Voltage | Single channel test range | -6V~6V | |
| Min. discharge voltage | -6V | |||
| Accuracy | ≤0.03%FS(@25℃±10℃),≤0.1%FS(@0-15℃,35-45℃) | |||
| Resolution | 1mV | |||
| Main channel Current | Single channel test range | ±200A | ||
| Min. output current | 20mA | |||
| Accuracy(automatic switching) | 20mA--50A:0.03%FS(@25℃±10℃) | |||
| 50A--100A:0.03%FS(@25℃±10℃) | ||||
| 100A--200A:0.03%FS(@25℃±10℃) | ||||
| Resolution | 1mA | |||
| Current start response time | <5ms(10%FS~90%FS) | |||
| Time | Resolution | 10ms | ||
| Auxiliary temperature (Optional) | Range | ﹣20℃~100℃ | ||
| Accuracy | ±1℃(0℃~70℃) | |||
| Resolution | 0.1℃ | |||
| Power | Output power | Single channel continuous working power 1200W | ||
| Stability | ±0.1%FS | |||
| 5 | Communication | LAN | ||
| 6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
| Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
| Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
| Cycle time | Max. 9999 | |||
| Programmable step | Max. 9999 | |||
| Nested loop | Max. 10 layers | |||
| Step time range | No limit, support h, min, s | |||
| Data record | Maximum recording time:10ms,Voltage≤0.03%FS,Current≤0.03%FS | |||
| Program feature | Each step has one or multiple exit | |||
| 7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
| Process list | Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc. | |||
| Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
| 8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
| 9 | Data saving | Save as files | ||
| 10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity. | ||
| Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc. | ||||
| 11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection. | ||
| Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection. | |||
| Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
| 12 | Barcode scan | Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system. | ||
| 13 | Sampling terminals | Four-polar sampling. Copper nose or other fixture. | ||
| 14 | Energy consumption | Discharge power feedback to grid | ||
| 15 | Cooling method | Forced Fan-cooled | ||
| Noise | Less than 70dB | |||
| IP grade | IP20 | |||
| 16 | Repair | Modularized structure. Can be replaced or repair with spare parts. | ||
Product Specification
| Cabinet size | 600*800*1980(Device direct line out) |
| 600*990*1980(Device with adapter) | |
| Weight | ≤300KG |
| Channels number | 32CH |
Working Environment
Power Supply (Single Unit): AC 380V ±10%, 50 Hz ±5%.
Power Supply (Complete Cabinet): AC 380V ±10%, 50 Hz ±5%.
Maximum Input Power (Complete Cabinet): 51.2 kW (32 channels).
Ambient Temperature: 0–45°C.
Ambient Humidity: ≤ 85% RH (non-condensing).
Operating Environment: Free from strong vibration, corrosive gases, and flammable or explosive gases.