Ürün ayrıntıları

Created with Pixso. Evde Created with Pixso. Ürünler Created with Pixso.
Battery Comprehensive Tester
Created with Pixso.

100V Battery Comprehensive Tester 30A Charge 120A Discharge For Lithium Battery

100V Battery Comprehensive Tester 30A Charge 120A Discharge For Lithium Battery

Marka Adı: ACEY
Model Numarası: ACEY-BIT100-30A120A
Adedi: 1 takım
Fiyat: USD 2280~6520/Set
Ödeme Şartları: Banka havalesi, PayPal, L/C, Western Union, MoneyGram
Tedarik Yeteneği: 200 Takım/ay
Ayrıntılı Bilgiler
Menşe yeri:
Çin
Sertifika:
CE
Garanti:
1 Yıl Garanti ve Ömür Boyu Destek
Satış Sonrası Hizmet:
7/24 Teknik Destek
Gerilim aralığı:
0~100V
Şarj akımı:
0 ~ 30A
Boşaltma akımı:
0~120A
Mevcut çözünürlük:
0,001A
Akım doğruluğu:
±(%0,1 RD + 0,1 FS)
Giriş Güç Kaynağı:
AC 200~240V 50/60HZ
Ambalaj bilgileri:
Kontrplak durumda
Vurgulamak:

industrial Battery Comprehensive Tester

,

internal resistance Battery Comprehensive Tester

,

Comprehensive lithium battery testing machine

Ürün Tanımı

100V Battery Comprehensive Tester 30A Charge 120A Discharge For Lithium Battery

 

 

Product Description

ACEY-BIT100-30A120A battery comprehensive tester is used for comprehensive testing of finished Lithium battery packs. The equipment supports dual functions and can be used as both an electronic load and a comprehensive battery tester. The test items include battery open-circuit voltage, AC internal resistance, continuous charge current, continuous charge voltage, continuous discharge current, continuous discharge voltage, charge overcurrent protection current, discharge overcurrent protection current, short-circuit protection time, overcurrent delay time, and voltage after testing.

 

Test Items

No. Test Item Description Test Range
1 Voltage Test The tester measures voltage twice: first as open-circuit voltage, and second after all tests are completed, especially after short-circuit protection testing, to verify battery status. The second voltage is slightly lower than the first. 0–100 V
2 AC Internal Resistance Measures battery AC internal resistance at 1000 Hz. 0–4000 mΩ
3 Charge Overcurrent Protection Current Verifies whether the battery activates protection when charging current exceeds the limit. This function is critical to prevent damage to the protection PCB. If not available, continuous charge current is selected instead. 0–30 A
4 Continuous Charge Current For batteries without charge overcurrent protection, the charge current is typically set to match the charger rating. 0–30 A
5 Continuous Charge Voltage Monitoring During continuous charging, upper and lower voltage limits can be set to determine whether the battery voltage exceeds the allowed range. 0–100 V
6 Discharge Overcurrent Protection Current & Delay Time When discharge current exceeds a preset value, protection is triggered automatically. Parameters are usually set according to the battery specification. 0–120 A
7 Continuous Discharge Current Evaluates whether the battery can sustain normal discharge current. PCB faults may cause failure to maintain continuous discharge. 0–120 A
8 Continuous Discharge Voltage Monitoring During continuous discharge, voltage upper and lower limits can be set to determine whether the battery voltage is out of range. 0–100 V
9 Short-Circuit Protection Time Measures protection response time when battery terminals are shorted. Faster response provides better protection. Typical requirement is below 1000 μs. Excessive short-circuit time may result from high loop resistance and should be analyzed. Maximum short-circuit withstand current is approximately 5000 A. ≤1000 μs
10 Test Current Impact No surge or impact current is generated during testing, ensuring no damage to the battery protection PCB.

 

Main Technical Parameter

  • Voltage range: 0–100 V, accuracy ±0.05% rdg + 0.05% fs (customizable for higher voltage accuracy upon request).
  • Internal resistance range: 0–2000 mΩ, accuracy ±0.05% rdg + 0.05% fs.
  • Charge current range: 0–30 A, accuracy ±0.05% rdg + 0.05% fs.
  • Discharge current range: 0–120 A; at maximum voltage, continuous discharge current up to 120 A is supported, with accuracy ±0.05% rdg + 0.05% fs (higher current ranges can becustomized upon request).
  • Overcurrent delay time: 0–30 s, accuracy ±0.05% rdg + 0.05% fs.
  • Short-circuit time: 0–2000 μs, accuracy ±0.05% rdg + 0.05% fs.
  • NTC measurement range: 0–100 kΩ, accuracy ±0.05% rdg + 0.05% fs.
  • R1 measurement range: 0–100 kΩ, accuracy ±0.05% rdg + 0.05% fs.
  • Operating power supply: AC 200–240 V.
  • Maximum operating power: 3000 W (at maximum charging current).
  • Installation environment: well-ventilated and dry industrial site.
  • Operating conditions: temperature −10 °C to 40 °C, humidity 10% to 90%.

 