5V 400A 16 Channels Regenerative Prismatic Battery Formation And Capacity Grading Machine
Product Description
ACEY-BCT5400-16P lithium ion cell grading machine is used to test the capacity of prismatic batteries through cyclic charging and discharging tests. The equipment is compatible with a wide range of cell sizes, supporting terminal spacing from 50 to 170 mm, lengths of 90 to 220 mm, thicknesses of 15 to 100 mm, and heights of 80 to 310 mm, making it suitable for diverse production requirements.
System Working Principle
The system is PC-controlled for command execution and data collection, with a keypad for manual operation and status display. During charging, AC power is converted to DC to regulate battery charging; during discharging, the energy is converted back to AC and fed into the factory grid, enabling efficient energy regeneration.
Test process flow:
Power on and check the battery ➡ Edit the test process(Set formation and capacity grading parameters according to the battery type) ➡ Send the test process to the system ➡ Perform formation and capacity testing ➡ Formation and capacity test completed ➡ Set sorting parameters(Define different capacity grades based on requirements) ➡ Send sorting parameters and carry out cell sorting ➡ Test completed, remove the batteries
Supported Battery Dimensions
| Length | 90–220 mm |
| Thickness | 15–100 mm |
| Height | 80–310 mm |
| Terminal spacing | 50–170 mm |
Main Technical Parameter
| Number of equipment channels | The whole machine has 16chs |
| External dimension | L112xW145xH190cm |
| Case color | Standard gray / black (customizable) |
| Clamp type | Flat head clamp (optional with crocodile clamp) |
| Clamp Spacing | 109mm |
| Channel control mode | Each channel can be started, stopped, suspended, continued and protected independently. |
| Each channel has independent constant voltage and current. Hardware control circuit | |
| The accuracy of charging current and discharging current of each channel can be calibrated automatically by software | |
| Working power supply | Three phase five wire AC380V土10%, 50Hz |
| Power factor | 0.99 @220VAC, Full Load, Grid THDu ≤2% |
| Current Harmonics | <5% @220VAC, Full Load, Grid THDu ≤2% |
| Power Section Efficiency Indicators | Charge ≥80% ,Discharge≥70% |
| Power consumption work | ≤30KW |
| Equipment failure rate | <1% |
| Power component protection function | Grid voltage overrun protection |
| Grid frequency overrun protection | |
| Heat dissipation mode | Natural wind in, upward exhaust |
| Voltage measurement range | DC-0.3~5V |
| Battery voltage range | Charge DC -0.3~4.5V; discharge DC 4.5~2V |
| Constant voltage range | DC 2~4.5V |
| Voltage accuracy | ±(0.05% reading + 0.05% full), resolution ratio 1mV |
| Voltage stability | ≤(±1mV) |
| Current range | Charge DC 800mA~400A |
| Discharge DC 800mA~400A | |
| Current accuracy | ±(0.05% reading + 0.05% full), resolution ratio 1mV |
| Current stability | ≤(±1mA) |
| Current rise time (90% load) | ≤50MS |
| Channel start-up time (90% load) | ≤50MS |
| Control mode | Computer control, can control the whole cabinet with scanning function |
| Communication mode | 485s port communication (port rate 57600)/ TCP |
| Process settings | Up to 32 steps and 256 cycles can be set |
| Charging mode | Constant current; constant pressure; constant current & pressure |
| Charging cut-off conditions | Voltage, current, time, capacity |
| Discharge mode | Permanent flow, constant power, constant resistance |
| Discharging cut-off conditions | Voltage, time, and capacity |
| Protection function | 1. Charging over-voltage protection, charging under-voltage protection |
| 2. Discharge over-voltage protection, discharge under-voltage protection | |
| 3. Charge and discharge voltage trend protection | |
| 4.Voltage fluctuation protection | |
| 5.Current fluctuation protection | |
| 6. Battery reverse connection protection, hardware protection mode | |
| 7. Power tube short circuit protection | |
| 8. Channel capacity alarm protection (timeout protection) | |
| 9. Voltage sampling dropout protection | |
| 10. Voltage outlier protection | |
| 11. Capacity outlier protection | |
| 12. Open voltage detection before the process starts, stop opening the channel with voltage exceeding the limit | |
| 13. Power failure protection, data breakpoint recovery | |
| Time frame | 0~3000 min / step in min |
| Time accuracy | ≤±0.1% |
| Sampling inspection cycle | 1s-60s optional |
| Battery sorting | Divide according to capacity, time, open-circuit voltage, discharge platform, etc. |
| Data processing | Can record voltage, current, time, capacity etc, automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, median voltage, provide data curve and cycle diagram; can output text, excel, word or mdb format data file |
| Basic function of software | 1. The software supports various connections, such as manual pause continuation, software shutdown continuation, power outage, disconnection in equipment communication, abnormal stop continuation; |
| 2. Support bar code scanning, scanning one-dimensional code, QR code, channel jump scanning, loading scanning and other scanning methods; | |
| 3. Local test detailed data storage, can view the current test data and historical data of each channel at any time, have data and curve corresponding two ways, and support excel report in single or batch form, and can set the test end automatic data export according to the need. | |
| 4. Support capacity sorting, and grade the battery sorting; | |
| 5. Support the qualified judgment after the test, and judge the pass / ng results according to the specified cycle capacity, voltage, time and other information; | |
| 6. Support various step protection and global voltage, current, temperature abnormal protection, and abnormal alarm, support battery pack overcharge, overdischarge protection test; | |
| 7. Support channel parallel (according to equipment); | |
| 8. Support unit conversion; | |
| 9. Support database server background storage or MES docking; | |
| 10. Software offline protection; |