| نام تجاری: | ACEY |
| شماره مدل: | ACEY-BA100200-6 |
| مقدار تولیدی: | 1 مجموعه |
| قیمت: | USD 1980~29600/Set |
| شرایط پرداخت: | T/T، PayPal، L/C، Western Union، MoneyGram |
| توانایی عرضه: | 200 مجموعه در ماه |
100V 200A Energy-feedback Lithium Battery Pack Testing Aging Machine For Lithium/Lead-acid/NiMH/NiCd Battery
Product Description
ACEY-BA100200-6 battery aging test cabinet is used for aging and performance testing of various battery packs, including ternary lithium, lithium iron phosphate, lead-acid, nickel-metal hydride, and nickel-cadmium batteries. It supports both common-port and separate charge/discharge port battery packs, with an adjustable voltage range of 10V to 100V and a charge/discharge current range of 100mA to 200A, meeting a wide variety of testing requirements.
It is widely used for battery module production testing in battery manufacturing plants, high-current charge and discharge verification for EV/HEV power battery systems, comprehensive battery performance evaluation, and routine battery module maintenance in battery factories and charging stations.
Equipment Functional Highlights
Main Technical Parameter
| NO | Item | Function requirement | ||
| 1 | Channel | 6 | ||
| 2 | Action Mode | Completely independent | ||
| 3 | Main channel work mode | Charging: constant current and constant voltage charging CCCV.&CC | ||
| Discharge: constant current discharge CD.& CP | ||||
| Rest, Stop | ||||
| Main channel test abort condition | Time, voltage, current, capacity, etc | |||
| 4 | Voltage of main channel | Votage range of Charge&discharge | 10V-100V | |
| Accuracy |
±(0.05%RD+0.05%FS) |
|||
| Resolution | 1mV | |||
| Current of main channel | Maximum output current | 200A | ||
| Minimum output current | 100mA | |||
| Accuracy |
±(0.05%RD+0.05%FS) |
|||
| Resolution | 1mA | |||
| Power | Output | Single channel continuous operation maximum power 20KW | ||
| Auxiliary channel parameter cut-off function | The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. | |||
| 5 | Control program | Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. | ||
| Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend. | ||||
| Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. | ||||
| Cycle times | Max 9999 | |||
| Work step time unit | h,min,s are available | |||
| Data logging | Min 5S | |||
| 6 | Data display method | Loop List | cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. | |
| Process List | process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
| Detailed list | There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. | |||
| 7 | Data export method | The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. | ||
| 8 | Curve Type | X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. | ||
| Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. | ||||
| 9 | Software protection | Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. | ||
| Hardware protection | Battery reversal, over-current protection, over-voltage protection, short-circuit protection. | |||
| Alarm function | The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. | |||
| 10 | Output wire | Four-wire connection mode with separate current and voltage lines. | ||
| 11 | Maintainability | Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. | ||
| 12 | Test channel and battery pack connection method |
OT terminal connection, OT terminal overcurrent greater than 100A, all channels connected one-to-one. |
||
| 13 | Equipment testing environment and technical requirements | Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant | ||
| Working environment: temperature -10℃~40℃ / humidity: 10%~90% | ||||
Product Display
![]()
![]()