rincian produk

Created with Pixso. Rumah Created with Pixso. Produk Created with Pixso.
Lithium Cell Grading Machine
Created with Pixso.

OEM 8CH Regenerative Battery Pack Test System 6V 100A 48 Channel

OEM 8CH Regenerative Battery Pack Test System 6V 100A 48 Channel

Nama merek: ACEY
Nomor Model: ACEY-HRCDS-6V100A-48CH
MOQ: 1 set
Harga: USD 2480~23200/Set
Ketentuan Pembayaran: T/T, PayPal, L/C, Western Union, MoneyGram
Kemampuan Penyediaan: 200 Set/bulan
Informasi Rinci
Tempat asal:
Cina
Sertifikasi:
CE
Jaminan:
Garansi 1 Tahun Dengan Dukungan Seumur Hidup
Layanan purna jual:
Dukungan Teknis 24/7
Jumlah saluran:
48 saluran
Kisaran pengukuran tegangan:
-6V ~ 6V
Akurasi Tegangan:
±0,03% FS, resolusi 1mV
Rentang Saat Ini:
Pengisian & Pengosongan 20mA~100A
Akurasi saat ini:
±0,03% FS, resolusi 1mA
Baterai yang Kompatibel:
Baterai Li-ion/Baterai timbal-asam/Baterai Ni-Cd/Baterai Ni-MH
Kemasan rincian:
Kasus kayu lapis
Menyoroti:

OEM Battery Pack Test System

,

6V 100A Battery Pack Test System

,

8CH regenerative battery pack test system

Deskripsi Produk

6V 100A 48 Channels Battery Charge Discharge Test Equipment For Li-ion/Lead-acid/Ni-Cd/Ni-MH Battery

 

 

Product Description

ACEY-HRCDS-6V100A-48CH battery charge discharge tester is designed for cycle life testing and quality inspection of  Lithium-ion, Lead-acid, Nickel-Cadmium (Ni-Cd), and Nickel-Metal Hydride (Ni-MH) batteries.

 

Supported Test Functions:

  • Battery cycle life testing
  • Battery capacity testing
  • Battery charge performance testing
  • Battery discharge performance testing
  • Battery state-of-charge retention testing
  • Battery charge/discharge efficiency testing
  • Battery overcharge and over-discharge rate tolerance testing

 

Equipment Features

  • Current supports multiple ranges: 0.02A-25A (accuracy ≤0.03%FS), 25A-50A (accuracy ≤0.03%FS), 50A-100A (accuracy ≤0.03%FS).
  • Minimum discharge voltage -6V
  • High Reliability and Low Noise: Compact and flexible for laboratory use, with high energy density.
  • Energy Feedback (Up to 75% Grid Efficiency): Bi-directional energy feedback during charge and discharge reduces electricity costs and air-conditioning expenses caused by heat dissipation.
  • Fixture Contact Impedance Monitoring: Prevents safety issues due to poor terminal contact or oxidation from prolonged use.
  • CCCV Charging: Smooth CCCV transition with no voltage or current spikes, effectively preventing localized heating, tab delamination, micro-short circuits, and unwanted protection triggers on PCBs.
  • Stable and Accurate Current/Voltage Sampling: Uses high-precision, wide-dynamic-range ADC units for long-term measurement stability and accuracy.
  • Dynamic Load (DL) Protection: Safeguards batteries during charge/discharge, preventing arcing or current surges caused by loose connectors, and protects sensitive electronic components such as MOSFETs and fuses.

  • Voltage Clamping Function: Limits voltage during battery protection activation or device abnormality to prevent damage to the battery or battery protection board.

  • ECD & EVD Protection: Prevents charging or discharging of batteries that fail selection criteria, avoiding unnecessary protection triggers.

 

Main Technical Parameter

No. Item ACEY-HRCD6V100A-48CH
1 Main channels 8CH/ module
2 Channel working mode Completely independent.
3 Main channel working mode Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV.
Discharge: CD, CP, CR, DCCV.
Still, Pulse test, Working Condition test, DCIR test.
Main channel test cutoff condition Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc.
4 Main channel Voltage Single channel test range -6V~6V
Min. discharge voltage -6V
Accuracy ≤0.03%FS(@25℃±10),≤0.1%FS(@0-15℃,35-45℃)
Resolution 1mV
Main channel Current Single channel test range ±100A
Min. output current 20mA
Accuracy(automatic switching) 20mA--25A:0.03%FS(@25℃±10)
25A--50A:0.03%FS(@25℃±10)
50A--100A:0.03%FS(@25℃±10)
Resolution 1mA
Current start response time 5ms(10%FS90%FS)
Time Resolution 10ms
Auxiliary temperature (Optional) Range 20℃100℃
Accuracy ±1℃(0℃70℃)
Resolution 0.1℃
Power Output power Single channel continuous working power 600W
Stability ±0.1%FS
5 Communication LAN
6 Control program Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online.
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc.
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature.
Cycle time Max. 9999
Programmable step Max. 9999
Nested loop Max. 10 layers
Step time range No limit, support h, min, s
Data record Maximum recording time:10ms,Voltage≤0.03%FS,Current≤0.03%FS
Program feature Each step has one or multiple exit
7 Data display Cycle list Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc.
Process list Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc.
Detail list Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc.
8 Data export Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc.
9 Data saving Save as files
10 Curves type X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity.
Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc.
11 Software protection Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection.
Hardware protection Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection.
Warning function Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically.
12 Barcode scan Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system.
13 Sampling terminals Four-polar sampling. Copper nose or other fixture.
14 Energy consumption Discharge power feedback to grid
15 Cooling method Forced Fan-cooled
Noise Less than 70dB
IP grade IP20
16 Repair Modularized structure. Can be replaced or repair with spare parts.

 

Product Specification

Cabinet size 600*800*1980(Device direct line out)
600*990*1980(Device with adapter)
Weight 300KG
Channels number 48CH

 

Working Environment

  • Power supply of the whole cabinet: AC 380V±10%, frequency: 50HZ±5%.
  • Maximum input power of the whole cabinet: 41.15 kW (48CH)
  • Working temperature: 0℃~ 45℃.
  • Humidity: less than ≤ 85%R.H (non-condensing).
  • No severe shake, no corrosive gases, no flammable or explosive gases around.

 

Product Display