| ব্র্যান্ড নাম: | ACEY |
| মডেল নম্বর: | ACEY-HRCDS-6V1000A-6CH |
| MOQ: | 1 সেট |
| দাম: | USD 2480~35000/Set |
| অর্থ প্রদানের শর্তাবলী: | টি/টি, পেপাল, এল/সি, ওয়েস্টার্ন ইউনিয়ন, মানিগ্রাম |
| সরবরাহের ক্ষমতা: | 200 সেট/মাস |
6V 1000A 6 Channels Regenerative Lithium Battery Charge Discharge Cycler Tester
Product Description
ACEY-HRCDS-6V1000A-6CH battery charge discharge cycle tester features a high-reliability, low-noise design with high power density. It is designed for capacity testing, cycle life evaluation, charge and discharge performance analysis, and quality inspection. The regenerative energy feedback system delivers up to 70% efficiency, significantly reducing power consumption and heat generation. Seamless CCCV charging ensures smooth transitions without current or voltage spikes, providing safe and stable testing conditions. Combined with high-precision measurement and comprehensive protection functions, the system offers dependable performance for cycle life testing and quality control of lithium-ion, lead-acid, Ni-Cd, and Ni-MH batteries in both production and R&D environments.
Supported Test Functions
Equipment Features
Main Technical Parameter
| No. | Item | ACEY-HRCD6V1000A-6CH | ||
| 1 | Main channels | 1CH/ module | ||
| 2 | Channel working mode | Completely independent. | ||
| 3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV. | ||
| Discharge: CD, CP, CR, DCCV. | ||||
| Still, Pulse test, Working Condition test, DCIR test. | ||||
| Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
| 4 | Main channel Voltage | Single channel test range | -6V~6V | |
| Min. discharge voltage | -6V | |||
| Accuracy | ≤0.05%FS | |||
| Resolution | 1mV | |||
| Main channel Current | Single channel test range | ±1000A | ||
| Min. output current | 200mA | |||
| Accuracy(automatic switching) | 200mA--100A:0.05%FS(@25℃±10℃) | |||
| 100A--200A:0.05%FS(@25℃±10℃) | ||||
| 200A--1000A:0.05%FS(@25℃±10℃) | ||||
| Resolution | 1mA | |||
| Current start response time | <5ms(10%FS~90%FS) | |||
| Time | Resolution | 10ms | ||
| Auxiliary temperature (Optional) | Range | ﹣20℃~100℃ | ||
| Accuracy | ±1℃(0℃~70℃) | |||
| Resolution | 0.1℃ | |||
| Power | Output power | Single channel continuous working power 5000W | ||
| Stability | ±0.1%FS | |||
| 5 | Communication | LAN | ||
| 6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
| Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
| Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
| Cycle time | Max. 9999 | |||
| Programmable step | Max. 9999 | |||
| Nested loop | Max. 10 layers | |||
| Step time range | No limit, support h, min, s | |||
| Data record | Maximum recording time:10ms,Voltage≤0.05%FS,Current≤0.05%FS | |||
| Program feature | Each step has one or multiple exit | |||
| 7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
| Process list | Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc. | |||
| Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
| 8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
| 9 | Data saving | Save as files | ||
| 10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity. | ||
| Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc. | ||||
| 11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection. | ||
| Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection. | |||
| Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
| 12 | Barcode scan | Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system. | ||
| 13 | Sampling terminals | Four-polar sampling. Copper nose or other fixture. | ||
| 14 | Energy consumption | Discharge power feedback to grid | ||
| 15 | Cooling method | Forced Fan-cooled | ||
| Noise | Less than 70dB | |||
| IP grade | IP20 | |||
| 16 | Repair | Modularized structure. Can be replaced or repair with spare parts. | ||
Product Specification
| Cabinet size | 600*800*1980(Device direct line out) |
| 600*990*1980(Device with adapter) | |
| Weight | ≤300KG |
| Channels number | 6CH |
Working Environment
Power Supply (Single Unit): AC 380V ±10%, 50 Hz ±5%.
Power Supply (Complete Cabinet): AC 380V ±10%, 50 Hz ±5%.
Maximum Input Power (Complete Cabinet):42.9 kW (6 channels).
Ambient Temperature: 0–45°C.
Ambient Humidity: ≤ 85% RH (non-condensing).
Operating Environment: Free from strong vibration, corrosive gases, and flammable or explosive gases.
Product Display
![]()