| Tên thương hiệu: | ACEY |
| Số mẫu: | ACEY-BIT100-30A200A |
| MOQ: | 1 bộ |
| Giá bán: | USD 2280~8810/Set |
| Điều khoản thanh toán: | T/T,PayPal,L/C,Western Union,MoneyGram |
| Khả năng cung cấp: | 200 bộ/tháng |
100V 30A Charge 200A Discharge Battery Comprehensive Tester For Lithium Battery
Product Description
ACEY-BIT100-30A 200A battery comprehensive tester is widely used in production lines and quality control for finished battery packs. Main test functions include open-circuit voltage, AC internal resistance, continuous charge and discharge current and voltage, charge and discharge overcurrent protection, short-circuit protection time, overcurrent delay, and post-test voltage, with testing started by SN input via infrared barcode scanner or automatically triggered by voltage detection, and is suitable for all series lithium-ion power batteries equipped with CH+, P+, CH−, and P− terminals.
Product Features
Test Items
| No. | Test Item | Description | Test Range |
| 1 | Voltage Test | The tester measures voltage twice: first as open-circuit voltage, and second after all tests are completed, especially after short-circuit protection testing, to verify battery status. The second voltage is slightly lower than the first. | 0–100 V |
| 2 | AC Internal Resistance | Measures battery AC internal resistance at 1000 Hz. | 0–4000 mΩ |
| 3 | Charge Overcurrent Protection Current | Verifies whether the battery activates protection when charging current exceeds the limit. This function is critical to prevent damage to the protection PCB. If not available, continuous charge current is selected instead. | 0–30 A |
| 4 | Continuous Charge Current | For batteries without charge overcurrent protection, the charge current is typically set to match the charger rating. | 0–30 A |
| 5 | Continuous Charge Voltage Monitoring | During continuous charging, upper and lower voltage limits can be set to determine whether the battery voltage exceeds the allowed range. | 0–100 V |
| 6 | Discharge Overcurrent Protection Current & Delay Time | When discharge current exceeds a preset value, protection is triggered automatically. Parameters are usually set according to the battery specification. | 0–200 A |
| 7 | Continuous Discharge Current | Evaluates whether the battery can sustain normal discharge current. PCB faults may cause failure to maintain continuous discharge. | 0–200 A |
| 8 | Continuous Discharge Voltage Monitoring | During continuous discharge, voltage upper and lower limits can be set to determine whether the battery voltage is out of range. | 0–100 V |
| 9 | Short-Circuit Protection Time | Measures protection response time when battery terminals are shorted. Faster response provides better protection. Typical requirement is below 1000 μs. Excessive short-circuit time may result from high loop resistance and should be analyzed. Maximum short-circuit withstand current is approximately 5000 A. | ≤1000 μs |
| 10 | Test Current Impact | No surge or impact current is generated during testing, ensuring no damage to the battery protection PCB. | — |
Main Technical Parameter
Product Display
![]()
![]()
![]()