| Marka Adı: | ACEY |
| Model Numarası: | ACEY-BA100600-1 |
| Adedi: | 1 takım |
| Fiyat: | USD 1980~19600/Set |
| Ödeme Şartları: | Banka havalesi, PayPal, L/C, Western Union, MoneyGram |
| Tedarik Yeteneği: | 200 Takım/ay |
100V Lithium Battery Pack 600A Charge 600A Discharge Aging Test Equipment For Lithium/Lead-acid/NiMH/NiCd Battery
Product Description
ACEY-BA100600-1 battery aging machine is designed for aging test of battery packs with common-port and separate charge/discharge port configurations, including ternary lithium, lithium iron phosphate, lead-acid, nickel-metal hydride, and nickel-cadmium batteries. It supports battery pack cycle life testing, capacity testing, charge and discharge characteristic testing, and temperature performance evaluation. The system provides a stable and adjustable output voltage range of 10V to 100V and an adjustable output current range of 100mA to 600A, ensuring reliable and precise test control across different applications.
Equipment Features
Software Workstep Setting Requirements
| NO | Item | Requirement |
| 1 | Charge | 1.Constant current charging, where the channel is output at a constant current and the current output is soft-started, with no current impact. |
| 2. Continuous mode of constant current and constant voltage charging, limited voltage output and current output at the same time, hardware automatic switching, with current hardware soft start, constant current to constant voltage without inrush current. | ||
| 2 | Discharge | Constant current discharge, the channel discharges at a constant current, the current control adopts soft start, no current shock. |
| 3 | Resting | The current circuit is cut off, but data collection is not stopped |
| 4 | Cycler | Cycle testing of work steps according to actual needs, multi-layer cycle nesting is possible |
| 5 | Stop | The channel is completely stopped and the battery circuit is completely disconnected from the device |
Main Technical Parameter
| NO | Item | Function requirement | ||
| 1 | Channel | 1 | ||
| 2 | Action Mode | Completely independent | ||
| 3 | Main channel work mode | Charging: constant current and constant voltage charging CCCV.&CC | ||
| Discharge: constant current discharge CD.& CP | ||||
| Rest, Stop | ||||
| Main channel test abort condition | Time, voltage, current, capacity, etc | |||
| 4 | Voltage of main channel | Votage range of Charge&discharge | 10V-100V | |
| Accuracy |
±(0.1%RD+0.1%FS) |
|||
| Resolution | 1mV | |||
| Current of main channel | Maximum output current | 600A | ||
| Minimum output current | 100mA | |||
| Accuracy |
±(0.1%RD+0.1%FS) |
|||
| Resolution | 1mA | |||
| Power | Output | Single channel continuous operation maximum power 15KW | ||
| Auxiliary channel parameter cut-off function | The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. | |||
| 5 | Control program | Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. | ||
| Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend. | ||||
| Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. | ||||
| Cycle times | Max 9999 | |||
| Work step time unit | h,min,s are available | |||
| Data logging | Min 5S | |||
| 6 | Data display method | Loop List | cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. | |
| Process List | process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
| Detailed list | There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. | |||
| 7 | Data export method | The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. | ||
| 8 | Curve Type | X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. | ||
| Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. | ||||
| 9 | Software protection | Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. | ||
| Hardware protection | Battery reversal, over-current protection, over-voltage protection, short-circuit protection. | |||
| Alarm function | The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. | |||
| 10 | Output wire | Four-wire connection mode with separate current and voltage lines. | ||
| 11 | Maintainability | Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. | ||
| 12 | Test channel and battery pack connection method |
OT terminal connection, OT terminal overcurrent greater than 100A, all channels connected one-to-one. |
||
| 13 | Equipment testing environment and technical requirements | Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant | ||
| Working environment: temperature -10℃~40℃ / humidity: 10%~90% | ||||
Product Display
![]()
![]()