| Marka Adı: | ACEY |
| Model Numarası: | ACEY-BT-5V6A |
| Adedi: | 1 takım |
| Fiyat: | USD 1130~1177/Set |
| Ödeme Şartları: | Banka havalesi, PayPal, L/C, Western Union, MoneyGram |
| Tedarik Yeteneği: | 500 Takım/Ay |
5V 6A 8 Channels Automatic Polymer Battery Cell Tester For Pouch Cell Making
Description
ACEY-BT-5V6A battery testing system is an 8‑channel analyzer capable of evaluating both polymer and cylindrical batteries across a current range of 12.0 mA to 6,000 mA and a voltage of up to 5 V. This versatile platform supports a wide array of battery testing applications, including electrode material research, performance characterization, small‑scale formation, capacity grading, and battery pack validation.
Specification
| Product Name: | Battery Testing Equipment 5V6A | ||||||
| Model No.: | ACEY-BT-5V6A | ||||||
| Input power | AC 220V ±10% / 50Hz | ||||||
| Input active power | 425W | ||||||
| Input Resistance | ≥1MΩ | ||||||
| Resolution | AD:16bit;DA:16bit | ||||||
| Voltage | Per Channel Voltage Range | 25mV~5V | |||||
| Discharge Min Voltage | 2V | ||||||
| Accuracy | ± 0.05% of FS | ||||||
| Stability | ± 0.05% of FS | ||||||
| Current | Per Channel Current Range | Range one:0.5mA~0.1A; Range two:0.1A~3A; Range three:3A~6A |
|||||
| Accuracy | ± 0.05% of FS | ||||||
| Constant Voltage Cut-off Current | 0.2mA;6mA;12mA | ||||||
| Stability | ± 0.05% of FS | ||||||
| Power | Per Channel Output Power | 30W | |||||
| Stability | ±0.1% of FS | ||||||
| Time | Current Response Time | (0~Full Range)<1ms | |||||
| Step Time Range | ≤(365*24)Hour/Step | ||||||
| Data Recording | Recording Condition | The minimum time interval:100ms The minimum voltage interval:10mV The minimum current interval:0.2mA;6mA;12mA |
|||||
| Record Frequency | 10Hz | ||||||
| Charge | Charge Mode | Constant Current Charge,Constant Voltage Charge,Constant Current and Constant Voltage Charge,CPC | |||||
| End Condition | Voltage,Current,Relative Time,Capacity,-△V | ||||||
| Discharge | Discharge Mode | CCD,CVD,CCVD,CPD,CRD | |||||
| End Condition | Voltage,Current,Relative Time,Capacity | ||||||
| Pulse | Charge | CCC | |||||
| Discharge | CCD | ||||||
| Min Pulse Width | 500ms | ||||||
| Pulse Number | Each pulse step supports 32 different pulses | ||||||
| Automated Switch | Automated switch from charge to discharge for each pulse | ||||||
| End Condition | Voltage, Test Time | ||||||
| Cycle | Loop Measure Range | 1~65535 times | |||||
| Max Steps Per Loop | 254 | ||||||
| Nested Loop | Nested loop Function,Max Support 3 Layers | ||||||
| Protection | Software Protection | Power-down Data Protection | |||||
| Off-line Testing Function | |||||||
| Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time | |||||||
| Noise | <85dB | ||||||
| Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | ||||||
| Channel Control Mode | Independent Control | ||||||
| Voltage and Current Testing Sample | 4-wire connecting | ||||||
| Database | MySQL Database | ||||||
| A Means of Communication of Upper Machine | TCP/IP Protocol | ||||||
| Data Output | EXCEL,TXT,Graph | ||||||
| Communication Interface | Ethernet Port | ||||||
| Per Unit Main Channels No. | 8 | ||||||
| Working Temperature Range | 0℃~40℃ | ||||||
| Storage Temperature Range | -10℃~50℃ | ||||||
| Working Environment Relative Humidity Range | 30% ~ 80% RH | ||||||
| Storage Environment Relative Humidity Range | 30% ~ 90% RH | ||||||
| Dimensions | 3U19”,W*D*H:480*380*130(mm) | ||||||
Product details
![]()