| ชื่อแบรนด์: | ACEY |
| เลขรุ่น: | เอซีย์-BA6060-24 |
| ขั้นต่ำ: | 1 ชุด |
| ราคา: | USD 2260~23500/Set |
| เงื่อนไขการจ่ายเงิน: | T/T, เพย์พาล, แอล/C, เวสเทิร์นยูเนี่ยน, MoneyGram |
| ความสามารถในการจําหน่าย: | 200 ชุด/เดือน |
60V 60A Battery Pack Charge Discharge Tester For Lithium/Lead-acid/NiMH/NiCd Battery
Product Description
ACEY-BA6060-24 battery pack charge discharge tester is mainly used for charge and discharge testing and related performance evaluation of battery packs, including NCM, LFP, lead-acid, and NiMH/NiCd types. All test channels operate independently. The system provides a stable and adjustable output voltage range of 10V–60V and an output current range of 100mA–60A. It is widely applied in battery module production testing for battery pack manufacturers, as well as charge and discharge testing of battery packs used in vacuum cleaners, power tools, and electric scooters.
Test Items
System Composition
The system mainly consists of a power supply module, AC/DC voltage conversion module (bidirectional AC/DC inverter), control module, power module, cooling system, data acquisition system (cell voltage, total voltage, current, and temperature), host computer data processing system, and cabinet structure.
Main Technical Parameter
| NO | Item | Function requirement | ||
| 1 | Channel | 24 | ||
| 2 | Action Mode | Completely independent | ||
| 3 | Main channel work mode | Charging: constant current and constant voltage charging CCCV.&CC | ||
| Discharge: constant current discharge CD.& CP | ||||
| Rest, stop | ||||
| Main channel test abort condition | Time, voltage, current, capacity, etc | |||
| 4 | Voltage of main channel | Voltage range of Charge&discharge | 8V-60V | |
| Accuracy | ±(0.05%RD+0.05%FS) | |||
| Min discharge voltage | 8V(port voltage) | |||
| Resolution | 1mV | |||
| Current of main channel | Maximum output current | 60A | ||
| Minimum output current | 100mA | |||
| Accuracy | ±(0.05%RD+0.05%FS) | |||
| Resolution | 1mA | |||
| Power | Output | Single channel continuous operation maximum power 3.6KW | ||
| Auxiliary channel parameter cut-off function | The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. | |||
| 5 | Control program | Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. | ||
| Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend. | ||||
| Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. | ||||
| Cycle times | Max 9999 | |||
| Work step time unit | h,min,s are available | |||
| Data logging | Min 5S | |||
| 6 | Data display method | Loop List | cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. | |
| Process List | process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
| Detailed list | There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. | |||
| 7 | Data export method | The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. | ||
| 8 | Curve Type | X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. | ||
| Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. | ||||
| 9 | Software protection | Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. | ||
| Hardware protection | Battery reversal, over-current protection, over-voltage protection, short-circuit protection. | |||
| Alarm function | The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. | |||
| 10 | Output wire | Four-wire connection mode with separate current and voltage lines. | ||
| 11 | Maintainability | Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. | ||
| 12 | Test channel and battery pack connection method | Alligator clamp | ||
| 13 | Equipment testing environment and technical requirements | Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant | ||
| Working environment: temperature -10℃~40℃ / humidity: 10%~90% | ||||
| 14 | Communication function | smbus,I2C,HDQ,SPI,CAN,RS485 | ||
| (Optional) | Real-time reading of parameter information (voltage, temperature, current, capacity) in BMS supports DBC import and self-editing. | |||
Product Display
![]()
![]()