| Brand Name: | ACEY |
| Model Number: | ACEY-BCT560-64P |
| MOQ: | 1 Set |
| Price: | USD 6600~15960/Set |
| Payment Terms: | T/T,PayPal,L/C,Western Union,MoneyGram |
| Supply Ability: | 200 Sets/Month |
The ACEY-BCT560-64P is a comprehensive lithium battery charge and discharge testing system featuring 64 independent channels. Standard equipment includes customized flat-head clamps, with optional alligator clips available. This system is designed for testing voltage, capacity, and various performance parameters of cylindrical, prismatic, and pouch cells. With its stable and precise performance, it's ideal for battery capacity grading and quality assessment applications.
| Cell Type | Item | Range |
|---|---|---|
| Prismatic Cells | Length | 80-300 mm |
| Thickness | 15-75 mm | |
| Width | 80-230 mm | |
| Tab Center Distance | 50-250 mm | |
| Cylindrical Cells | Length | 80-230 mm |
| Diameter | 26-72 mm |
| Number of Channels | 64 channels in total |
| Cabinet Color | Standard gray-white / gray-black, customizable |
| Fixture Type | Flat-head clamps, optional alligator clips |
| Fixture Spacing | 81 mm |
| Loading Method | Motorized upward pushing |
| Channel Control Mode | Independent constant-current and constant-voltage source per battery |
| Working Power Supply | Three-phase five-wire AC380V±10%, 50Hz |
| Power Factor | 0.99 @220VAC, full load, grid THDu ≤2% |
| Current Harmonics | <5% @220VAC, full load, grid THDu ≤2% |
| Power Module Efficiency | Charging ≥80%, discharging ≥70% |
| Working Power Consumption | ≤22.6 kW |
| Equipment Failure Rate | <1% |
| Status Indicator | Three-color status indicator light |
| Cooling Method | Natural air intake, upward air exhaust |
| Voltage Measurement Range | DC 0-5V |
| Battery Voltage Range | Charging: DC 0-4.5V; Discharging: DC 4.5-2V |
| Constant Voltage Range | DC 2-4.5V |
| Voltage Accuracy | ±(0.5‰ of reading + 0.5‰ of full scale) |
| Voltage Control Resolution | 1 mV |
| Voltage Sampling Resolution | 1 mV |
| Current Range | Charging: DC 120mA-60A; Discharging: DC 120mA-60A |
| Current Accuracy | ±(0.5‰ of reading + 0.5‰ of full scale) |
| Current Control Resolution | 1 mA |
| Current Sampling Resolution | 1 mA |
| Current Rise Time | ≤50 ms, 90% load |
| Channel Start Time | ≤50 ms, 90% load |
| Control Method | Computer-controlled operation, whole-cabinet control, with scanning system |
| Communication Method | RS485 serial communication, baud rate 57600 / TCP communication |
| Process Setting | Up to 64 working steps and 256 cycles can be set |
| Charging Modes | Constant current, constant voltage, constant current & constant voltage |
| Charging Cut-off Conditions | Voltage, current, time, capacity, -ΔV |
| Discharging Modes | Constant current, constant power, constant resistance |
| Discharging Cut-off Conditions | Voltage, time, capacity |
| Time Range | 0-3000 minutes per step |
| Time Accuracy | ≤±1‰ |
| Sampling Inspection Cycle | 1-60 seconds, selectable |
| Battery Sorting | Sorting by capacity, time, open-circuit voltage, discharge platform, etc. |
| Data Processing | Comprehensive data recording and analysis with multiple export formats |