rincian produk

Created with Pixso. Rumah Created with Pixso. Produk Created with Pixso.
Battery Pack Tester
Created with Pixso.

100V 20A Charge 20A Discharge Regenerative Battery Pack Test System For Lithium Battery

100V 20A Charge 20A Discharge Regenerative Battery Pack Test System For Lithium Battery

Nama merek: ACEY
Nomor Model: ACEY-BA10020-24
MOQ: 1 set
Harga: USD 2260~13990/Set
Ketentuan Pembayaran: T/T, PayPal, L/C, Western Union, MoneyGram
Kemampuan Penyediaan: 200 Set/bulan
Informasi Rinci
Tempat asal:
Cina
Sertifikasi:
CE
Jaminan:
Garansi 1 Tahun Dengan Dukungan Seumur Hidup
Layanan purna jual:
Dukungan Teknis 24/7
Jumlah saluran:
24 saluran
Rentang tegangan:
10V-100V
Rentang Saat Ini:
0,1~20A (Pengisian & Pengosongan)
Ketepatan:
±(0,05%RD+0,05%FS)
Daya Keluaran:
Maks. 2kW (Saluran Tunggal)
Kemasan rincian:
Kasus kayu lapis
Menyoroti:

100V high voltage battery test system

,

Regenerative high voltage battery test system

,

Regenerative battery life cycle tester

Deskripsi Produk

100V 20A Charge 20A Discharge Regenerative Battery Pack Test System For Lithium Battery

 

 

Product Description

ACEY-BA10020-24 regenerative battery pack test system is mainly used for cycle life testing, capacity testing, charge/discharge performance testing, and temperature characteristic testing of battery packs, including NCM, LFP, lead-acid, and NiMH/NiCd batteries. The output voltage range is adjustable and stable from 10V to 100V, and the output current range is adjustable and stable from 100mA to 20A. It is suitable for aging tests of battery packs used in vacuum cleaners, power tools, and electric scooters.

 

System Composition

The system mainly consists of a power supply module, AC/DC voltage conversion module (bidirectional AC/DC inverter), control module, power module, cooling system, data acquisition system (cell voltage, total voltage, current, and temperature), host computer data processing system, and cabinet structure.

 

Equipment Functions

  • Independent channels for battery charge/discharge and performance testing. Current and voltage programmable within rated range.
  • Safety protections: reverse-polarity, voltage/current line monitoring, power-off, over-current, over-voltage, and over-temperature protection.
  • Customizable test step sequences with multi-level nested cycles.
  • Each channel has independent programmable constant current and constant voltage sources.
  • Test interruption recovery supported; unfinished steps resume automatically after abnormal events.
  • Abnormal capture: alarms and test pause if voltage/current exceed set limits.
  • Real-time data logging for traceability and fault analysis.
  • Curve analysis: select cycles and combine multiple curves.
  • Soft-start output for charge/discharge to prevent current spikes.
  • CCCV charging with smooth CC/CV transition and no voltage/current spikes.
  • Supports external charger monitoring; automatic cutoff if current drops below threshold.
  • Software scan-to-start (barcode/QR), centralized control, and remote monitoring supported.

 

Main Technical Parameter

NO Item Function requirement
1 Channel 24
2 Action Mode Completely independent
3 Main channel work mode Charging: constant current and constant voltage charging CCCV.&CC
Discharge: constant current discharge CD.& CP
Rest, Stop
Main channel test abort condition Time, voltage, current, capacity, etc
4 Voltage of main channel Votage range of charge 10V100V
Votage range of discharge 10V100V
Accuracy ±(0.05%RD+0.05%FS)
Resolution 1mV
Current of main channel Maximum output current Discharge & Charge 20A
Minimum output current 100mA
Accuracy ±(0.05%RD+0.05%FS)
Resolution 1mA
Power Output Single channel continuous operation maximum power 2000W
Auxiliary channel parameter cut-off function The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions.
5 Control program Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files.
Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend.
Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit.
Cycle times Max 9999
Work step time unit h,min,s are available
Data logging Min 5S
6 Data display method Loop List cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc.
Process List process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc.
Detailed list There are record serial number, system time, accumulated time, voltage, current, energy, power, etc.
7 Data export method The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL.
8 Curve Type X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely.
Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely.
9 Software protection Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection.
Hardware protection Battery reversal, over-current protection, over-voltage protection, short-circuit protection.
Alarm function The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection.
10 Output wire Four-wire connection mode with separate current and voltage lines.
11 Maintainability Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period.
12 Test channel and battery pack connection method Alligator clamp
13 Equipment testing environment and technical requirements Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant
Working environment: temperature -10℃40℃ / humidity: 10%90%

 