| Nama merek: | ACEY |
| Nomor Model: | ACEY-BA100100-12 |
| MOQ: | 1 set |
| Harga: | USD 2650~29694/Set |
| Ketentuan Pembayaran: | L/C,T/T,Western Union,MoneyGram |
| Kemampuan Penyediaan: | 200 Set/bulan |
100V 100A Energy Saving Lithium Battery Pack Life Cycle Tester For Battery Assembly Line
Product Description
ACEY-BA100100-12 is mainly used for battery charging and discharging and related battery characteristics testing, the test channels are completely independent.Through software programming control, the battery can be charged and discharged with any programmed range of current and voltage.
Application
1.Applicable to ternary , lithium iron phosphate , lead-acid , nickel-metal hydride nickel-cadmium and other battery pack aging test.
2.Applicable to the same port battery pack and sub-port battery pack.
3.Equipment aging battery pack voltage range 10V ~ 100V, charging and discharging current range 100mA~100A adjustable
4.Battery manufacturing enterprises battery module production testing.
5.EV/HEV power battery system high current charging and discharging detection.
6.High-current charging and discharging testing of battery modules, battery performance testing, etc
7.Daily battery module maintenance in battery factories and charging stations
Product Parameters
| NO | Item | Function requirement | ||
| 1 | Channel | 8 | ||
| 2 | Action Mode | Completely independent | ||
| 3 | Main channel work mode | Charging: constant current and constant voltage charging CCCV.&CC | ||
| Discharge: constant current discharge CD.& CP | ||||
| Rest, Stop | ||||
| Main channel test abort condition | Time, voltage, current, capacity, etc | |||
| 4 | Voltage of main channel | Votage range of Charge&discharge | 8V-100V | |
| Accuracy | (0.1%RD+0.1%FS) | |||
| Resolution | 1mV | |||
| Current of main channel | Maximum output current | 100A | ||
| Minimum output current | 500mA | |||
| Accuracy | (0.1%RD+0.1%FS) | |||
| Resolution | 1mA | |||
| Power | Output | Single channel continuous operation maximum power 10KW | ||
| Auxiliary channel parameter cut-off function | The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. | |||
| 5 | Control program | Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. | ||
| Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend. | ||||
| Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. | ||||
| Cycle times | Max 9999 | |||
| Work step time unit | h,min,s are available | |||
| Data logging | Min 5S | |||
| 6 | Data display method | Loop List | cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. | |
| Process List | process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
| Detailed list | There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. | |||
| 7 | Data export method | The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. | ||
| 8 | Curve Type | X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. | ||
| Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. | ||||
| 9 | Software protection | Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. | ||
| Hardware protection | Battery reversal, over-current protection, over-voltage protection, short-circuit protection. | |||
| Alarm function | The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. | |||
| 10 | Output wire | Four-wire connection mode with separate current and voltage lines. | ||
| 11 | Maintainability | Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. | ||
| 12 | Test channel and battery pack connection method | Alligator clamp | ||
| 13 | Equipment testing environment and technical requirements | Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant | ||