| ब्रांड नाम: | ACEY |
| मॉडल संख्या: | ACEY-HRCDS-60V30A-18CH |
| एमओक्यू: | 1 सेट |
| कीमत: | USD2579~19680/Set |
| भुगतान की शर्तें: | टी/टी, पेपैल, एल/सी, वेस्टर्न यूनियन, मनीग्राम |
| आपूर्ति करने की क्षमता: | 200 सेट/माह |
60V 30A Regenerative Battery Pack Cycle Life Test System For Li-ion/Lead-acid/Ni-MH/Ni-Cd Battery
Product Description
ACEY-HRCDS-60V30A-18CH Battery Pack Charge Discharge Test System is designed for life cycle aging tests and quality control in battery manufacturing and laboratory environments. It is widely used for testing lithium-ion, lead-acid, nickel-cadmium, and nickel-metal hydride batteries.
This system provides stable and accurate charge and discharge control, making it suitable for both production verification and R&D evaluation. It supports a wide range of battery performance tests, including:
With reliable performance and flexible test modes, ACEY-HRCDS-60V30A-18CH battery life cycle tester helps manufacturers and laboratories evaluate battery consistency, durability, and safety throughout the development and production process.
Key Advantages
Main Technical Parameter
| No. | Item | ACEY-HRCDS-60V30A | ||
| 1 | Main channels | 1CH/ module | ||
| 2 | Channel working mode | Completely independent | ||
| 3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV | ||
| Discharge: CD, CP, CR | ||||
| Still | ||||
| Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
| 4 | Main channel Voltage | Single channel test range | 0V-60V | |
| Min. discharge voltage | 6V | |||
| Accuracy | ±0.05%FS+0.05%RD | |||
| Resolution | 1mV | |||
| Main channel Current | Single channel test range | ±30A | ||
| Min. output current | 60mA | |||
| Accuracy | ±0.05%FS+0.05%RD | |||
| Resolution | 1mA | |||
| Current start response time | <10ms(10%FS~90%FS) | |||
| Time | Resolution | 1s | ||
| Auxiliary voltage (Optional) | Range | DC:0-5V | ||
| Accuracy | ±0.05%FS | |||
| Resolution | 1mV | |||
| Auxiliary temperature (Optional) | Range | ﹣20℃~100℃ | ||
| Accuracy | ±1℃(0℃~80℃) | |||
| Resolution | 0.1℃ | |||
| Power | Output power | Single channel continuous working power 1800W. | ||
| Stability | ±0.1%FS+0.1%RD | |||
| 5 | Communication | LAN | ||
| Battery BMS communication | Support CAN 2.0A, CAN 2.0B; RS485 communication; | |||
| Support DBC import, realize data reading with BMS CAN, and participate in process control | ||||
| 6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
| Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
| Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
| Cycle time | Max. 9999 | |||
| Programmable step | Max. 9999 | |||
| Nested loop | Max. 10 layers | |||
| Step time range | No limit, support h, min, s | |||
| Data record | Time≥1s, Voltage≥0.1%FS, Current ≥0.1%FS | |||
| Program feature | Each step has one or multiple exit. | |||
| 7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
| Process list | Process number, working mode, process time, capacity, power, medium voltage, cut-off voltage, cut-off current, etc. | |||
| Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
| 8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
| 9 | Data saving | Save as files | ||
| 10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity | ||
| Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc. | ||||
| 11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection | ||
| Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection | |||
| Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
| 12 | Barcode scan | Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system. | ||
| 13 | Sampling terminals | Four-polar sampling. Copper nose or other fixture. | ||
| 14 | Energy consumption | Discharge power feedback to grid | ||
| 15 | Cooling method | Forced Fan-cooled | ||
| 16 | Noise | Less than 70dB | ||
| IP grade | IP20 | |||
| 17 | Repair | Modularized structure. Can be replaced or repair with spare parts. | ||
| 18 | Software update | Provide regular software upgrade services until the hardware is incompatible. | ||
Equipment Specification
| Cabinet size | 600*800*1980mm |
| Weight | ≤300KG |
| Channels number | 18CH |
Product Display
![]()
![]()
![]()